|
Product |
Requirements |
Model 1 |
Model 2 |
Model 3 |
Model 4 |
Model 5 |
|
Power (VA) |
KPCT-500 |
KPCT-650 |
KPCT-1000 |
KPCT-1500 |
KPCT-2000 |
|
Input |
Voltage |
145-290VAC±5V |
|
Frequency |
50Hz+/-10% |
|
Output |
Voltage
(AC Mode) |
190-250VAC |
|
Voltage
(Inverter Mode) |
220VAC
±5% |
|
Capacity |
500VA/300W |
650VA/360W |
1000VA/600W |
1500VA/880W |
2000VA/1200W |
|
Frequency (Inverter Mode) |
50Hz+/-0.5Hz |
|
Transfer Time |
2ms
typical |
|
Generator connection |
Normal
Working under the Generator |
|
Waveform |
modified-Sinewave |
|
Protection |
Spike &
Surge Suppression |
yes |
|
Over/Under Volt. |
Switch
to Bat. O / P when Mains over regulation range |
|
Over
load /short Circuit |
Fuse &
current limited for both Mains and Battery modes |
|
Battery |
Type |
Lead-Acid maintenance-free |
|
Dc Bus |
12V7.0Ah |
12V7.0Ah |
12V9.0Ah |
12V7.0Ah |
|
Number |
1 PC |
2 PCS |
|
Recharge time |
8hours≥90% |
|
Back up
time (one PC) |
8-15mins |
10-18mins |
20-30mins |
25-45mins |
30-45mins |
|
Physical |
Weight
(KGs) |
5 |
5.5 |
10.5 |
11.5 |
17 |
|
Shipping Wt. |
5.6 |
6 |
11 |
12 |
18 |
|
Product
Dimensions (mm) |
335*95*160 |
355*120*195 |
410*145*215 |
|
Packing
Dimensions (mm) |
435*395*275/ 2 PCS in 1 Carton |
435*395*275/ 2 PCS in 1 Carton |
495*250*335 |
|
Soft ware |
RS232
or USB option Windows & NT |
Auto
save & shut down |
|
Function |
Cold
start |
UPS
Start The Computer Even there Is no Main Power |
|
Automatic Charge |
Automatic Charge when UPS is off |
|
Automatic Restart |
Automatic Restart if main power coming within one hour |
|
Voltage
display |
220v/230v Optional following the real capacity |
|
Frequency |
50HZ/60HZ Optional following the real |
|
Beeping |
During
the battery mode ,the beeping optional |
|
Efficiency |
AC-AC |
1 |
|
DC-AC |
0.6 |
|
Acoustic |
Noise
level |
≤45dB |
|
Environmental |
Temperature |
-5-45
Degree C |
|
Humidity |
20% to
90% |
|
Power Outlets |
No. and
types |
2 SOCKETS |
3
SOCKETS |
4
SOCKETS |