KMBCS - Home
KMBCS - Company
KMBCS - Product
KMBCS - Service
KMBCS - Contact
FRP
Product   >> FRP   >> Cooling Tower   >>1010
  Kianco Composites FRP Cooling Tower Product
 
 

Features:

01. Tower body force structure: reinforced concrete frame structure, the natural vibration frequency 12HZ the runtime maximum amplitude is less than 0.14mm, steel manufacture is completed, the rust taken by the epoxy asphalt paint preservative treatment.
02. The concrete frame cooling tower the maintenance structure: polyester fiberglass, light weight, high strength, water resistance, corrosion resistance, aesthetic, anti-aging, service life of 20 years.
03. Concrete frame cooling towers hairdryer: the kinetic energy recovery type FRP hairdryer, hairdryer kinetic energy recovery value is less than 30%, hairdryer service life of 20 years. Hairdryer connections and fasteners using galvanized Luo bolt. Hairdryer surface is smooth, the overall rigidity, the outer surface with anti-aging, corrosion-resistant, does not fade, no cracks, excellent UV resistance gel coat resin production.
04. Concrete frame cooling tower fan: The design of the cooling tower of the Department of Engineering Mechanics, Tsinghua University a dedicated axial fan, leaf type for efficient airfoil blades made of FRP. The fan aerodynamic reasonable, high efficiency, large air volume, low noise, corrosion resistant.
05. The concrete framework cooling tower reducer: dedicated cooling towers, horizontal reducer, low noise, high efficiency, reliable oil lubrication, check
06. The concrete framework cooling tower motor: fan with motor outdoor motor Y series of well-known domestic manufacturers perform standard "rotary motor fixed and performance with GB755-2000. Motor protection class IP55, insulation class F power: 380V/50Hz / three-phase. Motor running safe, stable, no vibration and abnormal sound.
07. Packing: PVC PVC packing, steel, and the ability of the redistribution of water, small resistance, good thermal performance. Temperature -35 ¡æ to 65 ¡æ. Performance in line with the Department of Energy NDGJ88-89 "cooling tower water spray filler technology requirements. Life of 15 years, retardant oxygen index ¡Ý 30.
08. The water distribution system: with a good anti-clogging performance. A tubular water distribution system. Different tower location sprinklers the cloth water flow deviation <5% of the entire water distribution system in the 70% to 130% of rated flow within the water distribution uniformity. Under the conditions of use in the tower, its normal service life of 20 years.

 
Home Account Careers Investors Legal Media MSDS Privacy Site Map Terms Contact  
English     
Copyright 2007 Kianco Composites